CARDIAC › Tips and tricks › Subroutines
Return with TAC 99 when the accumulator is negative
Say a routine adds a reading to a running total, but a negative reading means there was nothing to read, and it should be skipped.
Done as in the last tip, the routine copies cell 99 first thing and returns through the copy, and a skipped reading jumps straight to the copy.
cell contents notes
10 040 INP 40 cells 10-18: four readings, each handed to the routine; then print the total
11 820 JMP 20
12 040 INP 40
13 820 JMP 20
14 040 INP 40
15 820 JMP 20
16 040 INP 40
17 820 JMP 20
18 541 OUT 41
19 900 HRS 00
20 199 CLA 99 cells 20-26: copy the return address first, then add the reading unless it is negative
21 626 STO 26
22 140 CLA 40
23 326 TAC 26 negative: skip it and go back
24 241 ADD 41
25 641 STO 41
26 000 the return address, copied from cell 99
40 000 the reading
41 000 the total
Step through the natural way in Cardigan
TAC doesn't write cell 99; only JMP does. So when the accumulator is negative, TAC 99 goes straight back to the caller, and here the accumulator is negative exactly when the reading should be skipped. The test that skips it is the return. The copy moves down to the one path that still needs it, and a skipped reading never pays for it.
cell contents notes
10 040 INP 40 cells 10-18: four readings, each handed to the routine; then print the total
11 820 JMP 20
12 040 INP 40
13 820 JMP 20
14 040 INP 40
15 820 JMP 20
16 040 INP 40
17 820 JMP 20
18 541 OUT 41
19 900 HRS 00
20 140 CLA 40 cells 20-21: a negative reading returns at once; TAC leaves cell 99 alone
21 399 TAC 99
22 241 ADD 41 cells 22-26: otherwise add it, and only now copy the return address
23 641 STO 41
24 199 CLA 99
25 626 STO 26
26 000 the return address, copied from cell 99
40 000 the reading
41 000 the total
Step through the CARDIAC way in Cardigan
Both add up 5 and 7 and print 12, and both take 19 cells. Copying first runs 34 instructions, and returning with TAC runs 30, two fewer for every reading skipped. A routine that ends negative on every path never has to copy cell 99 at all, which is why some programs go as far as storing their data as negative numbers. Cell 99 as the return address is the subroutine technique Brian L. Stuart's CARDIAC page shows, and TAC 99 is a small variation on it.
The Intel 8080 has this as one instruction. RM, return if minus, returns when the sign flag is set and otherwise carries on, and the Z80 kept it as RET M.
From the tips in
cardiac-code on GitHub. All the tips.